How Does an ILR Maintain the Required Temperature for Vaccines?
Wiki Article
The optimal ILR temperature assists in preserving the vaccine's potency and in forming a perfect cold chain in the field of medicine. The best ILR temperature for storing vaccines is between +2°C to +8°C. Bionics Scientific manufactures state-of-the-art Ice Lined Refrigerators (ILRs), which have efficient cooling capacity, hold over time during power outage, and consistent performance for various medical facilities like hospitals, blood banks, vaccination centers and many others in India as well as across the globe.
An Ice Lined Refrigerator is the refrigerator, which maintains a consistent temperature, even when there is no availability of electricity. This is not the case with domestic refrigerators because of the ice lining within the chamber.
What Is an Ice Lined Refrigerator?
Ice-Lined Refrigerators (ILR) are a type of refrigeration equipment used for storing vaccines, blood packs, and biological specimens. The function of ice lining is to maintain the required temperatures of ILRs (+2°C to +8°C) even when there is no electricity supply due to thermal stability.
Bionics Scientific offers ice-lined refrigerators which are compliant with ISO/CE and come with PU insulation, stainless steel compartment, and microprocessor digital controller.
Why Is the Correct ILR Temperature Important?
Vaccines will become ineffective when kept at temperatures other than the recommended ones. It is crucial to keep the correct ILR temperature to keep the vaccines effective, be able to store them safely, and reduce wastage of vaccines.
Some of the benefits that can be gained from the above features include maintenance of the efficacy of the vaccines at temperatures of +2°C to +8°C, extended hold over in case of power failures, prevention of freezing of sensitive vaccines, WHO cold chain recommendations, reduction of compressor cycling, and stable internal temperature in hot conditions.
ILR Temperature Guidelines
Adherence to the correct ILR temperature protocol is an important practice in order to ensure that vaccine quality is preserved through appropriate cold chain management.
Some of the recommendations are that the chamber temperature should be maintained within the range of +2°C to +8°C, temperature readings should be taken at least twice daily, the vaccines should be kept in the prescribed baskets, the lid should not be frequently opened, no food or drinks should be stored in the ILR, proper air circulation should be ensured, and the temperature measuring devices must be calibrated.
ILR Temperature Monitoring Best Practices
The accurate recording of the ILR temperature is essential for all immunization centers for the preservation of the quality of vaccines and for proper cold chain management.
Health care institutions need to have a digital temperature data logger, keep an ILR temperature logbook, note minimum and maximum temperature daily, conduct an investigation of any temperature excursion, and maintain the sensors and controller regularly.
It will help to reduce the wastage of vaccines and provide effective quality assurance programs.
ILR Temperature Chart
The standard ILR temperature chart can be used to quickly determine and maintain good storage conditions for vaccines and other products that are sensitive to changes in temperature.
Some of the recommended storage criteria include the ILR vaccine storage temperature which should be between +2°C and +8°C, the ambient temperature which should range between 10°C and 43°C, the hold-over time of 20-24 hours when there is no power and monitoring of the temperature twice a day.
Features of Bionics Scientific Ice Lined Refrigerators
Bionics Scientific provides highly reliable ILRs, which have been engineered for long-lasting performance and reliable storage of vaccines.
Some of the major features that these ILRs are equipped with include a temperature range of +2°C to +8°C, microprocessor digital controller, high-resolution LED/LCD display, prolonged hold-over capacity in case of any power failure, high-density PUF insulation, stainless steel interior chamber, forced air circulation, alarm system with audible and visual alerts, lockable casters, WHO-compliance, and ISO & CE certification.
Case Study: Reliable Vaccine Storage During a Power Failure
The vaccination site in Northern India used a Bionics Scientific Ice Lined Refrigerator after suffering from the loss of vaccines because of the numerous electrical power failures that occurred in the region.
When there was an electricity outage for sixteen hours, the ILR maintained ILR temperature from +2°C to +8°C without affecting the quality of the vaccines.
Therefore, vaccine wastage was prevented, immunization continued without fail, and the costs of replacing lost vaccines were minimized.
Applications of Ice Lined Refrigerators
Applications of bionics scientific ILRs include use in various places such as governmental vaccination program clinics, hospitals, blood banks, primary health care centers, diagnostic centers, medical colleges, pharmaceutical firms, and centers for vaccine distribution.
This is because these places need to maintain constant temperatures in order to preserve various medical materials including vaccines and biological specimens.
Why Choose Bionics Scientific?
One of India’s renowned producers of medical as well as laboratory refrigeration apparatus is Bionics Scientific. Having extensive manufacturing experience, the company provides custom-made Ice Lined Refrigerators in various sizes from small portable ones up to large-sized units for health care facilities.
All of the ILR units have been designed for efficient cooling capacity, economical running costs, and durability.
Frequently Asked Questions
What is the temperature required for ILR vaccine?
The required ILR vaccine storage temperature is +2°C to +8°C to keep the vaccine potent.
How does ILR differ from deep freezer?
An ILR keeps vaccines in the range of +2°C to +8°C, whereas a deep freezer keeps below 0°C.
What is the minimum temperature in ILR?
Minimum temperature is +2°C.
What is the full form of ILR with respect to temperature?
The full form of ILR is Ice-Lined Refrigerator.
What is the purpose of an ILR refrigerator?
The reason for its existence is to ensure safe storage of vaccines, blood bags, biological samples, and many other temperature sensitive pharmaceutical products.
What is the capacity of ILR?
The standard capacity starts from about 64 liters up to more than 300 liters, but customization is also possible.
Does IPV require freezing conditions?
No, IPV should be stored in ILR from +2°c to +8°c. Freezing of IPV is not allowed.
Where OPV is to be stored in ILR?
OPV is to be stored in vaccine baskets of ILR from +2°c to +8°c.
What will be the temperature of a vaccine freezer?
It would be between -15°c to -25°c depending upon vaccine needs.
What is the principle of operation of an Ice Lined Refrigerator?
This equipment uses frozen ice lining for thermal storage to keep temperatures constant during power outages.
What temperature do you store OPV at?
OPV is mostly stored following the immunization standards of the country. In facilities with ILR, the storage conditions are maintained within the recommended cold chain parameters.
How much does the ILR fridge cost?
This will depend on volume, insulation, type of control, alarms, data logger, among other customization needs. Get your customized quote from Bionics Scientific.
Contact Bionics Scientific Today
Are you looking for high-quality Ice Lined Refrigerators (ILRs) which can help in precise temperature control for vaccines, blood banks, or any other requirement in the healthcare industry? Bionics Scientific offers ILRs which are tested and certified by us for their efficient performance in terms of storage capacity and duration. Inquiry from potential buyers is appreciated.
Report this wiki page